Environmental precautions
Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. Do
not flush into surface water or sanitary sewer system. See Section 12 for additional
ecological information.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so. Cover powder spill with plastic sheet or
tarp to minimize spreading. Dike far ahead of liquid spill for later disposal.
Methods for cleaning up
Dam up. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal
binder, sawdust). Pick up and transfer to properly labeled containers. Soak up with inert
absorbent material.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Ensure adequate ventilation, especially in confined areas. Keep away from heat, sparks,
flame and other sources of ignition (i.e., pilot lights, electric motors and static electricity).
Take precautionary measures against static discharges. Use spark-proof tools and
explosion-proof equipment. All equipment used when handling the product must be
grounded. Use with local exhaust ventilation. Use personal protective equipment as
required. Do not breathe dust/fume/gas/mist/vapors/spray. Avoid contact with eyes. Avoid
breathing vapors or mists. Contents under pressure. Do not puncture or incinerate cans. Do
not stick pin or any other sharp object into opening on top of can.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep tightly closed in a dry and cool place. Keep in properly labeled containers. Keep
containers tightly closed in a cool, well-ventilated place.
Incompatible materials
Strong acids. Strong oxidizing agents. Chlorinated compounds.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
.
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Acetone
67-64-1
STEL: 500 ppm
TWA: 250 ppm
TWA: 1000 ppm
TWA: 2400 mg/m
3
(vacated) TWA: 750 ppm
(vacated) TWA: 1800 mg/m
3
(vacated) STEL: 2400 mg/m
3
The
acetone STEL does not apply to the
cellulose acetate fiber industry. It is
in effect for all other sectors
(vacated) STEL: 1000 ppm
IDLH: 2500 ppm
TWA: 250 ppm
TWA: 590 mg/m
3
Propane
74-98-6
: See Appendix F: Minimal
Oxygen Content
TWA: 1000 ppm
TWA: 1800 mg/m
3
(vacated) TWA: 1000 ppm
(vacated) TWA: 1800 mg/m
3
IDLH: 2100 ppm
TWA: 1000 ppm
TWA: 1800 mg/m
3
Butane
106-97-8
STEL: 1000 ppm (vacated) TWA: 800 ppm
(vacated) TWA: 1900 mg/m
3
TWA: 800 ppm
TWA: 1900 mg/m
3
1,2,4-Trimethylbenzene
95-63-6
- - TWA: 25 ppm
TWA: 125 mg/m
3
Titanium dioxide
13463-67-7
TWA: 10 mg/m
3
TWA: 15 mg/m
3
total dust
(vacated) TWA: 10 mg/m
3
total dust
IDLH: 5000 mg/m
3
Ethylene Glycol Butyl Ether
111-76-2
TWA: 20 ppm TWA: 50 ppm
TWA: 240 mg/m
3
(vacated) TWA: 25 ppm
(vacated) TWA: 120 mg/m
3
(vacated) S*
S*
IDLH: 700 ppm
TWA: 5 ppm
TWA: 24 mg/m
3
_____________________________________________________________________________________________
Page 4 / 11
28XXXXX ALL COLORS 
AEROSOLS