Contents 1. Safety Instructions --------------------------- 2 2. Regulatory Information --------------------------- 3 3. Precautions --------------------------- 4 4. Before setting up --------------------------- 5 5. Brief specifications of LCD Monitor ------------------------ 6 6. Setting up the LCD Monitor -------------------- 7 1) LCD Monitor’s Connectors -------------------- 7 2) Connecting the LCD Monitor -------------------- 8 7.
Safety Instructions Symbol Explanation RISK OF ELCTRIC SHOCK DO NOT OPEN CAUTION ! TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER(OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL MEDICAL EQUIPMENT 13XX E246477 WITH RESPECT TO ELECTRIC SHOCK.FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL60601-1, AND CAN/CSA C22.2 NO. 601.
Regulatory Information FCC RF INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
oxygen or with nitrous oxide. Precautions 1. Plug the power cord into a properly grounded outlet. There is the risk of electric shock. 2. If you hear a noise or smell smoke from the view box or power cord, unplug the power code immediately, and call service center. There is the risk of electric shock or fire. 3. Do not overload an electrical outlet with too many devices. There is the risk of fire. 4. Do not unplug from the outlet by pulling the power cord or when your hands are wet. 5.
Before setting up ● Install the LCD Monitor on a flat place. ● Don’t install in the place with much of water or moisture ● Put the LCD Monitor in a place with low humidity and a few of dust. ● Don’t overload an electrical outlet with too many devices. There is the risk of fire. ● Don’t expose the LCD monitor to the direct sun light. ● Keep the monitor away from high temperature. ● Operating Temperature is 10ºC ~ 40 ºC ● Do not place the monitor in hazardous position.
Brief Specification of LCD Monitor Brief Specifications Before setting up the LCD monitor, please read this manual to help your understanding of the 20.1 inch TFT-LCD Monochrome monitor. 1) 2) 3) 4) 5) 6) Resolution : 20.
Setting up the LCD Monitor Connectors ① ② ③ ④ ⑤ Descriptions No Name Cable Connections ① AC Inlet Connect the plug of AC power cord ② DVI Digital Video Interface connection from PC ③ RS-232C Use for factory set-up and service purpose ④ RS-232C Use for network system ⑤ USB(Up stream) Connect the USB cable to PC ⑥ USB(Down stream) Connect the USB cable to external equipments ⑥
Setting up the LCD Monitor Connecting the LCD Monitor 1) Connect the DVI-D signal cable to the signal port of the Graphic Card in your computer. 2) Connect the another connector of the DVI-D signal cable on the rear side of the monitor. 3) Connect the power cord to the AC inlet on the rear side of the monitor 4) Try to collect the cable and power cord like the below pictures 5) Turn on the monitor with the power switch of the user control port.
Adjusting the LCD Monitor Adjustment the height and the viewing angle - For optimal viewing, it is recommended to look at the full face of the monitor and then adjust the monitor’s height and angle to your own preference. - Hold the panel so that the monitor does not topple when you change the monitor’s height or angle - You are able to adjust the monitor’s height up to 110mm, angle up to 35degrees right and left, 35 degrees upward NOTE - Do not touch the LCD screen when you change the height or the angle.
Adjusting the LCD Monitor Adjustment OSD MENU contents LED LED MENU SELECT UP ☼ DOWN LOCK Indicate Monitor power state by LED color Monitor Power on / off Switch MENU SELECT ☼ UP DOWN LOCK ☼ Launch OSD Menu, Select Screen Menu. OSD Display will be disappeared automatically. Select screen Menu. Brightness control Menu shift left, Increase Data Value of Selected item. Increase brightness in case of Brightness Hot-Key. Menu shift right, Decrease Data Value of Selected item.
5) LUMINANCE SELECT brightness Calibration. Adjust the Brightness automatically to the target luminance value Before activating, connect the photo sensor between the front of screen and RS-232 port of LCD Monitor.
Appendix 24pin DVI Connector Pin Signal Pin Signal Pin Signal 1 T.M.D.S.Data2- 9 T.M.D.S.Data1- 17 T.M.D.S.Data0- 2 T.M.D.S.Data2+ 10 T.M.D.S.Data1+ 18 T.M.D.S.Data0+ 3 T.M.D.S.Data2/4 11 T.M.D.S.Data1/3 19 T.M.D.S.Data0/5 Shield Shield Shield 4 T.M.D.S.Data4- 12 T.M.D.S.Data3- 20 T.M.D.S.Data5- 5 T.M.D.S.Data4+ 13 T.M.D.S.Data3+ 21 T.M.D.S.Data5+ 6 DDC Clock 14 +5V Power 22 T.M.D.S. Clock Shield 7 DDC Data 15 Ground 23 T.M.D.S. Clock+ 8 N.
Appendix Specification ITEM Size MM50 MM30 20.1" MM20 21.3" 21.3" a-Si TFT active Type a-Si TFT active a-Si TFT active matrix matrix matrix Display size 399(H)x319(V)mm 433(H)x324(V)mm 432(H)x324(V)mm Brightness 850cd/m2 800cd/m2 800cd/m2 Viewing Angle 170(H),170(V) 170(H),170(V) 170(H),170(V) Pixel Pitch 0.156mm x 0.156mm 0.2115mm x 0.2115mm 0.270mm x 0.
Appendix Troubleshooting What you see Suggested Actions Screen is blank and Make sure that the power cord is firmly connected and the LCD power indicator is off monitor is on. No signal message Make sure that the signal cable is firmly connected to computer Make sure that the computer is turned on The display image is too Adjust the brightness dark or too light Screen is blank and The monitor is using its power management system.