7.6 Machining Parameters
23 – Template management
Available as of software version 625 952-05.
Select whether constants are to be output when templates are used.
24 – Parameter of the rechucking subroutines
Available as of software version 625 952-05.
With this parameter you influence the transfer parameters of the
rechucking subroutines. The following entries do not influence the
standard subroutines UMKOMPL and UMKOMPLA (see machining
parameter 21).
Template management
Output of constants with templates
0: Without output of constants
1: With output of constants
Parameters of the rechucking subroutines
EXPERT - LA
–99999: parameter transfer
–99998: no parameter transfer
Other numerical values: the entered numerical value is transferred
EXPERT - LB
–99999: parameter transfer
–99998: no parameter transfer
Other numerical values: the entered numerical value is transferred
. . .