Operation Manual

526 Organization mode of operation
8.2 Parameters
Settings for fixed cycles and units:
Parameters: processing / ... Meaning
... / General settings (602000) / ...
... / External safety clearance (SAR) [mm] (602005) External safety clearance on workpiece blank
... / Internal safety clearance (SIR) [mm] (602006) Internal safety clearance on workpiece blank
... / External on machined part (SAT) [mm] (602007) External safety clearance on machined part
... / Internal on machined part (SIT) [mm] (602008) Internal safety clearance on machined part
... / G14 for new units (602009) Default value for "tool change point G14."
... / Coolant for new units (602010) Default value for "coolant CLT":
0: Without (coolant)
1: Circuit 1 on
2: Circuit 2 on
... / G60 for new units (602011) Default value for "protection zone":
0: Active
1: Inactive
... / Safety clearance G47 [mm] (602012) Default value for "safety clearance G47":
... / Safety clearance, G147 infeed direction [mm] (602013) Default value for "safety clearance SCK"
... / Safety clearance, G147 plane [mm] (602014) Default value for "safety clearance SCI"
... / Oversize in X direction [mm] (602015) Default value for "oversize (X) I"
... / Oversize in Z direction [mm] (602016) Default value for "oversize (Z) K"