13
General Features
Test methods
Gage type FE and FE+NF
Gage type FE+NF
Automatic selection of the test method corre-
sponding to the base material
Magnetic induction method (ISO 2178, ASTM D7091, measurement of non-magnetic
coatings on magnetic substrates)
Eddy current method (ISO 2360, ASTM D7091, measurement of non-conductive coatings
on non-magnetic substrate metals)
Factory Calibration Each individual gage is factory calibrated at several reference points with the greatest care to
ensure the highest possible degree of trueness.
Data memory The memory content is preserved even when there is no voltage supply; subsequent viewing of
the measured single readings and evaluations
Gage variant Start with memory capacity of max. 10,000 measured readings in 1 batch
Gage variant High with memory capacity of 250,000 measured readings in 2500
batches and up to 100 calibrations
Evaluation Statistics
Gage variants Start and High with Batch template package Industrial: Display of mean
value, standard deviation, min/ max values and number of measurements per block, per
batch, coefficient of variation, number of measured values lower/upper the set limit val-
ues
Gage variant High with Batch template package Corrosion: Depending of the selected
measuring regulation; e.g. for SSPC-PA2, display per measurement location (Spot)/area
section (Area): Number of (Spots), mean value, coefficient of variation, min./max. values,
Range, measured readings < 80 %/> 120 % of limit values (coating thickness restriction
level 3)
Graphic Presentations
•Histogram
Run-Chart, showing the progress of measured readings
Probe Single tip axial probe with spring-loaded measuring system and with wear-resistant probe tip
built-in into gage
Probe tip radius: 2 mm, Probe tip material: Hard metal
Measurement interval More than 140 measurements per minute
Display of measurement acquisition Audible by a short beep and visual by colored illuminated LED; gage variant High: Additional
by gage vibration
Display for limit monitoring
Limit violation: Audible by 2 short beeps and visual by red illuminated LED; gage variant
High: Additional by gage vibration
Measured readings between the limits: Audible by 1 short beep and visual by green
illuminated LED; gage variant High: Additional by gage vibration
Languages German and English
Presettings for batches
Only available in gage variant High
Each new batch is created with a preset measurement unit and resolution for the displayed mea-
sured value. For the gage variant High-USB, the batch template package is also preselected here.
You can adapt these presettings to your requirements. However, you can also change the unit
of measurement and the resolution for the measured value display at any time in the batch that
has already been created.
Display
Graphic display with automatic flipping measuring presentation view (deactivatable) to
read measurement results in many different gage positions
Setting of brightness and contrast (definable for Office, Sunlight and Night)
Data transfer
Bluetooth/WiFi only available in gage variant
High
USB: Data transfer of single readings to a PC, Data import to MSExcel via PC-Datex soft-
ware; You can gratis download the PC-Datex program from Fischer-Homepage
Bluetooth/WiFi: Data transfer of measurements and data transfer of batches to App PHA-
SCOPE
®
PAINT; Creation and export of reports via App; You can gratis download the
App from Google Play Store and Apple App Store