Data Sheet

HELUTHERM
®
145MULTI-C
flexible,cross-linked,halogen-free,screened,EMC-preferredtype
PropertiesCablestructureTechnicaldata
Tinnedcopperconductor,finewire
acc.toDINVDE0295cl.5/
IEC60228cl.5
Temperature-resistantandhalogen-free
connectionandcontrolcable
Noflamepropagation
Goodabrasionandnotchresistance
Temperaturerange
flexing-35°Cto+120°C
fixedinstallation-55°Cto+145°C
inshort-circuit+200°C
Goodresistancetoweathering
Coreinsulation:cross-linked
polyolefin-copolymer
Resistanttoozone
Resistanttomelting,evenwhenin
contactwithasolderingironwith
temperaturesfrom300°Cto380°C
Coreidentificationblackcoreswith
continuouswhitenumbering
Nominalvoltage
upto1mm²U
0
/U300/500V
from1,5mm²U
0
/U450/750V
withprotectedfixedinstallation
from1,5mm²U
0
/U600/1000V
Coresstrandedinlayerswith
optimallaylength
Thematerialsusedduringmanufacturing
arecadmium-free,containnosilicone
andarefreefromsubstancesharmful
tothewettingpropertiesoflacquers
Foilwrapping
Tinnedcopperbraidedscreen,
approx.85%coverage
Testvoltage
3000V
Tests
Outersheath:cross-linked
polyolefin-copolymer
Flametestacc.to
DINVDE0482-332-3-22/
DINEN60332-3-22/IEC60332-3-22
Minimumbendingradius
flexing8xcableØ
fixedinstallation4xcableØ
Sheathcolour:black
Withmetermarking
Flametestacc.to
DINVDE0482-332-1-2/
DINEN60332-1-2/IEC60332-1-2
Note
Couplingresistance
max.250Ohm/km
Caloricloadvalues
see"TechnicalInformation"
Halogen-freeacc.to
DINVDE0482-754-1/
DINEN60754-1/IEC60754-1
AWGsizesareapproximateequivalent
values.Theactualcrosssectionisinmm².
Currentrating
see"TechnicalInformation"
Unscreenedanaloguetype:
HELUTHERM
®
145MULTI
Corrosivenessofcombustiongases
acc.toDINVDE0482-754-2/
DINEN60754-2/IEC60754-2
Approval
DNVGL
Smokedensityacc.to
DINVDE0482-1034-1+2/
DINEN61034-1+2/IEC61034-1+2
Fireprotectiononrailwayvehicles
acc.toEN45545-2
UV-resistantacc.toDINENISO4892-2
Application
Thesecross-linkedandtemperatureresistantwiringandcontrolcableswithenhancedfire-behaviourpropertiesareusedforwiringupthelighting
fixtures,heaters,electricmachines,switchingsystemsanddistributionswitchboards.Averylongservicelifeisalsogivenonaccountoftheirexcellent
high-temperaturestability.Thesecablesexhibitgoodresistancetoweatheringaswellasbeingverystabletotemperature,moisture,ozoneandUV
radiation.Thesecablesaretherforemainlyusedfortrafficcontrolsystemsanddiverseoutdoorapplications.Thedevelopmentofsmokeislowand
nocorrosivegasesareliberatedduringcombustionofthesehalogen-freecablesincaseoffire.Theriskoftoxicfumesisconsiderablylessintheevent
offirebecausethecoloricloadvaluesislower.Precioustimecanthusbewonforadisciplinedevacuation,andunnecessarylossoflifecanbeprevented.
Theextentofthedamagetocostlycontrolandmonitoringsystemsandtheconcreteandsteelstructuresofbuildingsandplantduetofireisreduced
bythis.Injuriestopersonsanddamagetomaterialscanbeprevented.Alowerconductorcrosssectionispossibleincertaincircumstancesbecause
ofthehighthermalloadandthussavingsinthespaceandweightrequiredcanbemade.
EMC =Electromagneticcompatibility
TooptimizetheEMCfeatureswerecommendalargeroundcontactofthecopperbraidingonbothends.
=ProductconformswithLow-VoltageDirective2014/35/EU.
AWG-No.Weight
app.kg/km
Cop.
weight
kg/km
OuterØ
app.mm
No.coresx
cross-sec.
mm²
Partno. AWG-No.Weight
app.kg/km
Cop.
weight
kg/km
OuterØ
app.mm
No.coresx
cross-sec.
mm²
Partno.
2436,016,05,02x0,2552194 2468,029,06,45x0,2552196
2495,037,07,57x0,25521972444,021,05,53x0,2552195
Continuation
18.03.2019/Dimensionsandspecificationsmaybechangedwithoutpriornotice.