4.6 WERA-RTU - WERA Real-Time-Unit
On newer versions:
DVI instead of VGA
For visual troubleshooting
information connect
monitor here.
Ethernet connection
To user interface pc
Figure 9: RTU Module
The real time unit controls data acquisition and stores measurement data on the user
interface pc. It communicates with the user interface pc and forwards all needed
parameters to the control unit.
4.7 WERA-CTU - WERA Control-Unit
The WERA control unit is programmed via an I
2
C Bus driven from the DIO 72. This unit
programs the sweep modules with the parameters received from the real time unit and
controls the receive and transmit signals. There are no front panel connections for this