4.17 Uninterrupted Power Supply (UPS)
It is strongly recommended to operate the WERA from an UPS unit. At least the WERA
User Interface PC should be connected to such a unit to guarantee a controlled and safe
ramping down of the PC in case of a power failure. The hard- and software of the ups
needs to be configured to safely shut down the PC in case of a longer power loss.
So a data link and software between the PC and ups is required.
In case of a very insecure power line, it might be better to operate the WERA system from
a UPS that continuously is generating the AC. Please contact factory to get more
information about these options.
4.18 Lightning Protection (-Plate) for WERA 8- channels
All WERA installations needs to be equipped with professional lightning protection units. If
the WERA electronics not housed in the original WERA container it is very important to
feed-in all cables via lightning protection filters. These filters are provided by Helzel, 8
surge protectors mounted on one plate. This plate needs to be connected to “Earth”
potential by means of a suited cable (a 10 mm
2
cable is enclosed). Please carefully check
these connections and if there are any doubts, please contact Helzel factory or a local
service company for help.
For the WERA 12-channel systems with AIP, the lightning protection is integrated in the
RIN filters.
Some models have a separate lightning protection plate, depending on the system
configuration.