Datasheet

Totalizing
Counters
Components
E N C O D E R S C O U N T E R S C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S
Technical data
tico 731
LCD display
Lithium battery
COUNT: count input for voltage
pulses 12-250 V AC/DC (20 Hz)
RESET: reset input for voltage
pulses 12-250 V AC/DC (20 Hz)
KEYLOCK: locking of the reset key
long case
TECHNICAL DATA
Operating temperature -10 ... 50 °C
Storage temperature -20 ... +60 °C
Electrical connection screw terminals, cable length < 30 m
Mounting with clamping frame
Front panel cutout 45 + 0.6 x 22 + 0.3 mm
Protection class (IEC 144) front side IP 54, terminals IP 20
Dynamic strength 10 m/s
2
(10 ... 150 Hz) according to IEC 68-T2-6
Shock stability 100 m/s
2
(18 ms) according to IEC 68-T2-27
General rating according to EN 61010-1, EN 50178, protective system II
Pulse shape any square wave (1:1 for max. frequency)
Input resistance < 50 kOhm (static)
Min. pulse length 25 ms (20 Hz)
Display 8-digit LCD, 7 mm
Supply voltage U
b
internal lithium battery
Current consumption DC lithium battery: 7 years
Inputs:
Amplitude thresholds high voltage input 20 Hz:
< 3 V and > 12 V, max. 250 V DC/AC
Active edge voltage input positive edge
Counting frequency 20 Hz
Control inputs:
Reset - manual reset via keyboard (can be locked)
- external reset with static behaviour,
positive circuit
Reset lock by means of bridge on the keylock input
ORDER NUMBER
TYPE 3
DIMENSIONS
CONNECTION DIAGRAM
0 731 3 0 1
Terminal assignment:
tico 731
Dimensions in mm
Clamping frame
Connecting terminal
Model tico 731
Software function
01 impulse counter
03 time counter (hhhh:mm:ss)
04 time counter (hhhhhh.hh)