Datasheet

Components
E N C O D E R S C O U N T E R S C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S
tico 731
Technical data
TYPE 4 LCD display
12-24 V DC supply voltage
COUNT: programmable count input
for voltage signal or contact,
frequency 7.5 kHz or 30 Hz
TECHNICAL DATA
Operating temperature -10 ... 50 °C
Strorage temperature -20 ... +60 °C
Electrical connection screw terminals, cable length < 30 m
Mounting with clamping frame
Front panel cutout 45 + 0.6 x 22 + 0.3 mm
Protection class (IEC 144) front side IP 54, terminals IP 20
Dynamic strength 10 m/s
2
(10 ... 150 Hz) according to IEC 68-T2-6
Shock stability 100 m/s
2
(18 ms) according to IEC 68-T2-27
General rating according to EN 61010-1, EN 50178, protective system II
Pulse shape any square wave (1:1 for max. frequency)
Input resistance < 50 kOhm (static)
Min. pulse length 17 ms (30 Hz), 70 µs (7.5 kHz)
Display 8-digit LCD, 7 mm
Supply voltage U
b
12 … 24 V DC*
Current consumption DC 12 … 24 V DC < 50 mA
Nominal data retention nonvolatile memory > 10 years
Count input:
Amplitude thresholds voltage input up to 7.5 kHz:
< 0.7 V and > 5 V, max. 30 V DC
Active edge negative or positive edge programmable
Counting frequency programmable: 7.5 kHz or 30 Hz (attenuated for contacts)
with position indicator 2 kHz: active edge positive
Control inputs:
Reset – manual reset via keyboard (can be locked)
– external reset with static behaviour, 30 Hz attenuated
same edge as with count input
Input 2: gate or second count channel; same edge as with count input
Reset lock programmable via front key
Transistor output signal PNP output
Voltage/switching current voltage supply minus 2 V; max. 10 mA
INPUT 2: control input for tempor-
ary locking of count input (gate) or
second count input with position
indicator
RESET: reset input
OUT: transistor output for preset
signal
long case
ORDER NUMBER
DIMENSIONS
CONNECTION DIAGRAM
0 731 4 0 1
Model tico 731
Software function
01 impulse counter
02 tachometer (1/min)
03 time counter (hhhh:mm:ss)
04 time counter (hhhhhh.hh)
06 bidirectional position indicator
Terminal assignment:
Input 2
Tr. out
12-24 VDC
0 V
Count
Reset
tico 731
Dimensions in mm
Clamping frame
Connecting terminal
* Not to be connected to a DC-Network. For further information see manual.
Counting frequency max. 7.5 kHz, transmission rate for numerical display: 1 kHz
INFORMATION
This is a class A device. This device may cause radio interferences in
residentialenviroments. In this case, the user may be asked to take
care of reasonable action.