Datasheet

Components 2000132 ENCODERS COUNTERS CONTROLLERS INDICATORS RELAYS PRINTERS CUTTERS
Technical data
TECHNICAL DATA
General
Counter
Tacho
Time-counter
Display LED or LCD, 6 digits, leading zero suppression, decimal point
Digit height LED 7.6 mm; LCD 9 mm
Supply voltage 12...24 VDC; 24 VAC; 115 VAC; 230 VAC; 50/60 Hz, depending
on version
Current consumption 12...24 VDC < 150 mA
100/115/230 VAC < 50 mA; including sensor supply
Sensor supply only when AC operated: 12 ... 30 VDC, max 50 mA
Data retention non-volatile memory > 10 years
Operating temperature 0 ... +50 °C
Storage temperature - 20 ... + 70 °C
Electrical connection screw terminals
Mounting with clamping frame
Protection class (IEC 144) front side IP 65, terminals IP 20
Vibrostability 10 m/s
2
(10...150 Hz) according to IEC 68-T2-6
Shock stability 100 m/s
2
(18 ms) according to IEC 68-T2-27
General design according to VDE 0411, DIN 57411, protection class II
Approvals UL + CUL E 96337
Amplitude thresholds < 2 V and > 8 V, max 40 VDC
Active edge programmable; positive with pnp input; negative with npn input
Pulse shape any (squarewave 1:1 for max. frequency)
Input resistance approx. 5 kOhm (static)
Counting frequency max. 5 kHz (2.5 kHz bi-directional)
Prescaler programmable from 0.001 to 9.999 (999.999)
Count inputs A, B - phase discriminator with single evaluation
- differential mode (add/sub)
- count direction mode
- totalizing mode (add/add)
Pulse length min. 17 ms (30 Hz), 100 µs (5 kHz)
Control input C - manual reset possible
- external reset, static or dynamic, programmable,
pulse length > 5 ms
- automatic reset when main preset has been reached
(programmable)
Relay changeover contact max. 250 VAC / 30 VDC, min. 5 V AC/DC
max. 1 A, min. 10 mA, delay < 5 ms
Transistor pnp output 12...24 VDC max 10 mA of DC-supply; 12…30 VDC
max. 10 mA of AC-supply
Method time interval (1/Tau)
Display range 1/min or 1/sec
Min input frequency 0.125 Hz = 8 sec
Alarms 2 alarms with programmable start-up-suppression
Time bases programmable; sec, min., h or hh.mm.ss
Resolution programmable 1; 0.1; 0.01; 0.001
Function single pulse measurement (short time meter) or cumulated
counting (hour meter)
Count mode pulse width or period measurement (start-stop)
DIMENSIONS
tico 732
Dimensions in mm
clamping frame
plug terminal