User Manual
36 37
When the application input is used as an additional count input, the above
mentioned input frequencies have to be reduced by the frequency of the ap-
plication input:
If mechanical contacts are triggered (i.e. relays, switches, Reed contacts, etc.),
the input frequency has to be damped (attenuated) to 30 Hz, so as to filter out
bounce pulses.
If damping to 30 Hz is selected, all inputs can be used at 30 Hz.
To reach these values the amplitude thresholds are to be hold.
(See technical data - chapter 10)
Signal
P 1 and P 2 are available as relay changeover contacts and electronic output
signals (PNP).
P 0 is available as an electronic output signal across the application output
(PNP).
If a signal is active, this will be shown on the LCD display.
Optionally, the multifunctional counter can be set to have the display flash if
one or all the preset values are acive.
This is also valid for Preset 0 (if no output has been assigned)
Signaltime:
1.) bistable: Cleared by electronic or manual reset.
P 0 + P 1= bistable – additionally cleared by signal 2
Attention: Signal 2 must not be bistable for automatic reset.
2.) monostable: Up to 9 fixed signal times are available between 0,02s and
10s. In addition, user times can be programmed between 0,01s to 599,99s.
3.) Range signals: active as long as the counter reading is within the adjusted
range.
Signals active on/off
During normal operation the relay is energized if the signal is active.
This behavior can also be inverted (also applicable to the transistor outputs).
General description of multifunctional counter General description of multifunctional counter
Application input/output:
Depending on the standard function, up to 11 (eleven) functions can be assig-
ned to the application input/output. Note, however, that only one of these
functions can be selected.
Further details are given in the Function Code Chapter.
Application – Set to preset 0
Programs the application input to act as a Set Input. The counter is set to Pre-
set 0, independently of the reset via input C or the keyboard.
This function is not available for tachometers.
Application keylock:
All keyboard functions can be locked (latched) individually
(Reset, P 0, P 1, P 2, Prescaler)
Lock mode: release after 10s, complete keylock or
keylock depending on keylock input (application input)
Our advice! After setting up the system, lock
(latch) all the keyboard functions that are not
allowed to be changed by the user.