User Manual
54 55
Function code F33, Display Row 1:
Lock
Preset 2
0*
P 2 Setting enabled
1
P 2 Setting locked / delayed
Function code F34, Display Row 1:
Lock
Prescaler
setting
0*
PSC setting enabled
1
PSC Setting locked / delayed
Function code F35, Display Row 1:
Lock
Mode
0*
10 seconds delay
1
Completely locked
2
Lock mode depends on keylock input
Pulse counter
6 Tachometer
6.1 Tachometer Description
(Supplementing the General Description given in Chapter 4)
Operation:
A tachometer measures the period (PNP: time from one rising edge to the next
one); NPN: time period from a falling edge to the next one), and converts and
displays this time in 1/sec or 1/min.
Tachometer Mode of Operation:
The following modes of tachometer operation can be selected:
Unidirectional counting;
Unidirectional counting with directional input;
Differential counting, summation (totalizing);
Phase discrimination (quad) with single, double or quadruple evaluation;
Indication of ratio A/B and
Indication of percentage (A-B) /A in %
Decimal point
Tachometer mode of operation 0-4 (function code F1)
The decimal point only serves for better legibility and does not change the va-
lue.
Tachometer mode of operation 5 + 6 (function code F1)
The decimal point is included in the calculation and increases the resolution.
Output signals Mode of operation:
The tachometer uses the following limit values:
P 1 and 2 are limit (range) signals
Signal 1 is active at the displayed value of < P 1 and
Signal 2 is active at the displayed value of > P 2
Signal 0 is active at the displayed value of > P 0; (application output)
Tachometer