User Manual

100 101
Function code F2, Display Row 1:
Edge
Evalua-
tion
Quadrat.
Evalua-
tion
0*
Single evaluation
1
Double evaluation
2
Quadruple evaluation
Function code F3, Display Row 1:
PNP/
NPN-Lo-
gic
0
NPN 8 V-Level
1*
PNP 8 V-Level
2
NPN TTL-Level
3
PNP TTL-Level
Function code F4, Display Row 1:
Input
damping
(At-
tenuat)
0
30 Hz damping (e.g. for mechanical
contacts)
1*
F max. (see chapter 4 and 10)
Batch Counter
Function code F5, Display Row 1:
Set / Re-
set- Mode
0*
Reset to 0
1
Automatic reset to 0 when Preset
value 2 is reached
2
Sets to Preset value 2
3
Automatic set to Preset 2 after
reaching 0
Function code F6, Display Row 1:
Dynamic/
static
Reset
0*
Static Reset (reset as long signal is
applied)
1
Dynamic Reset (ready to count after
reset, even if reset signal is applied
for a longer time)
Function code F9, Display Row 1:
Output
signal
0*
Active On
1
Active Off
Batch Counter