User Manual

108 109
2
Directional count output
3*
Count input, adding
4
Count input, subtracting
5
Reset counter and Batch counter or
2nd totalizer
6
Resets only counter
7
Resets only Batch counter or 2nd
totalizer
8
Gate input
9
Keylock input
10
Hold input (display memory)
11
Teach input Count value becomes P
2
12
Set-input (sets to Preset 0)
Batch Counter
Should you have a counter with interface, the
additional function codes F24 - F27 are descri-
bed in the seperate manual for the interface
version.
Function code F30, Display Row 1:
Lock Re-
set key
0*
Keyboard reset enabled
1
Keyboard reset locked / delayed
Function code F31, Display Row 1:
Lock
Preset 0
Setting
0*
P 0 Setting enabled
1
P 0 Setting locked / delayed
Function code F32, Display Row 1:
Lock
Preset 1
Setting
0*
P 1 Setting enabled
1
P 1 Setting locked / delayed
Batch Counter