User Manual
92 93
Function code F13, Display Row 1:
Decimal
Point
0*
No decimal point
1
1 decimal place
2
2 decimal places
3
3 decimal places
4
4 decimal places
Function code F14, Display Row 1:
Display
flashes
0*
No flashing
1
Flashes as long as P 0 is active
2
Flashes as long as P 1 is active
3
Flashes as long as P 2 is active
4
Flashes as long as one Preset is active
Shift Counter
Function code F15, Display Row 1:
Display in
2nd Row
0
Preset 0
1
Preset 1
2*
Preset 2
3
Prescaler
4
Partial sum 1
5
Partial sum 2
6
Totalizer
Function code F17, Display Row 1:
Power-On
Reset
0*
Restores the counter value
1
Reset at Power On
Function code F18, Display Row 1:
Output
Signal
Memory
0
Restart signal time after power fail
output switches
1*
Do not restart signal time after power
fail
Shift Counter