High-level does not exceed the up-
per amplitude threshold; low-level
does not fall below the lower amp-
litude threshold
Qualified electrician
Continuous reset signal is applied Qualified electrician
Continuous gate signal is applied Qualified electrician
Incorrect
counting of
counter/
tachometer
Prescaler value is not correct Skilled personnel
Phase discriminator - edge evalua-
tion not correctly adjusted (F2)
Skilled personnel
Input frequency too high (F4) Skilled personnel
Keyboard Re-
set not possi-
ble
Keys are locked (F30 + F35) Skilled personnel
Presetting not
possible
Keys are locked (F31, F32, F33 +
F35)
Skilled personnel
Prescaler ad-
justment not
possible
Keys are locked (F34+ F35) Skilled personnel
Signal 0, 1 or
2 not received
Signal deactivated (F10, F11, F12) Skilled personnel
User signal time adjusted to 0,000 Skilled personnel
Malfunctions
14 Spare Parts
Warning!
Danger due to faulty spare parts!
The use of incorrect or faulty spare parts may cause damage, malfunction or
even total breakdown and safety hazards. Therefore, please make sure only to
use the original spare parts provided by the manufacturer.
The multifunctional counter may only be opened by the manufacturer.
Exclusively outer components are available as spare parts.
The order numbers are given in Chapter 17.