User Manual
24 25
3.5 Overview of Operating Elements
Setup and Operation
Display Mode Reset
123456 up + dn 0
noitcnuf dradnatS = 2 teserP = pu + E
retemaraP noitcnuF = 1 teserP = nd + E
semit langiS = 0 teserP = tfihs + E
up + shift = Prescale
r
Programming Mode Standard Funct. Function parameters:
Pulse counter Operat. Mode Count frequency
Tachometer Decimal point Reset Behavior
yromeM tuptuOedoM-teseR/teSremiT
Shift counter Display-Mode Keylock
Batch counter Output signals npn/pnp selection
Applic. Input/Output
+ many other function parameters
E + up at power on
E + dn at power on
up + shift at power on
E
Setup and Operation
3.6 Programming the Standard Function
The device described here is a multifunctional counter, which can be program-
med for a variety of functions, i.e. pulse counter, tachometer, timer, shift
counter or batch counter functions. The first step is to set the standard func-
tion (the factory setting of the device is the “pulse counter” setting).
Now continue with the programming of the function codes (Chapters 5-9) or
User Times (Chapter 3.10)
Programming mode Change function
setting:
Save, return to counter
operation
+
or
Keep pressed and
switch voltage on
simultaneously
press press
Function code Fn, Display Row 1
Function No.
Display
Row 2
Setting of
Standard
Function
0*
Pulse counter
1
Tachometer
2
Timer
3
Shift Counter
4
Batch Counter