User Manual

28 29
Setup and Operation
Programming
mode
Position
flashes:
Set position: Save and return
to
display mode
+
or
Preset 2 press press press
+
+
Zero in
Preset 1
+
Set Preset
Preset 0
Setup and Operation
3.9 Prescaler programming
By pressing the Up + Shift keys simultaneously you can change to the Presca-
ler Programming Mode.
In the Programming mode, the position to be changed is selected by means of
the shift key. The selected position will start flashing. Use the shift key again
to move by one position to the right. Then use the UP or Down key to incre-
ment or decrement the position by 1. It is not possible to save a value of
00,0000. In this case the system will save 01,0000.
Use the E key to leave the programming mode and return to the display mode.
Your entries will be saved.
On leaving the programming mode, all the presets are recalculated because
not all the values may be attained with a prescaler value of >1. Therefore, the
presets have to be checked and corrected as necessary after saving the presca-
ler.
If no key is pressed for more than 16 seconds in the programming mode, the
counter will automatically return to the display mode. In this case, however,
no entries will be saved except the last value saved with the E-key.
Press the Up and Down keys simultaneously to set the prescaler to 01,0000.
Programming
mode
select a position:
(starts flashing)
Set position Save and return to
display mode
+
or
press press press press
Set prescaler
+
set to 01,0000