User Manual

40 41
Pulse counter
Summation (totalizer) input (F1= A A r) = 5
Input A
Adding
Input B
Adding
Input C
Reset
Counter reading 1 2 4 5 6 701
Phase discriminator (F1 = QUAd r) = 6 Change of rotating direction
Channel A
Channel B
Input C
Reset (dynamic)
Counter reading single 1 2 3 4 5 40-1
Evaluat. (F2=0)
Counter reading double 123456789870-1 -2
Evaluat. (F2=1)
Counter reading quad. 12345678910 11 12 13 14 15 16 17 17 16 15 14 13 0 -1 -2 -3 -4
Evaluat. (F2=2)
Unidirectional counting (F1 = C G r) = 0
Input A
Counter input
Input B
Gate
Input C
Reset
Counter reading 1 2 3 3 4 501
Directional input(F1= C d r) = 1
Input A
Counter input
Input B
Directional input
Input C
Reset
Counter reading
1 2 3 2 3 401
Differential input (F1= A S r) = 3
Input A
Adding
Input B
Subtracting
Input C
Reset
Counter reading 1 2 3 2 1 201
Pulse counter
5.3 Signal diagrams - Output signals
Output signals monostable
Coincidence signals P 0 (F10), P 1 (F11), P 2 (F12) monostable
t
eseR Preset 0 Preset 1 Preset 2
Counter reading
P 1 (Relay)
Signal
time
P 2 (Relay)
Signal
P 0 electronic time
(Application output)
P 1 electronic
Signal
time
P 2 electronic
Signal time
Signal time
Output signals bistable
Coincidence signal time P 0 (F10) monostable P 1 (F11), P 2 (F12) bistable
Counter reading
P 1 (Relay)
P 2 (Relay)
Signal
P 0 electronic time
(Application output)
P 1 electronic
P 2 electronic
bistable
bistable
bistable
bistable
Preset 0 Preset 1 Preset 2 Reset