User Manual

44 45
Pulse counter
Function code F1, Display Row 1:
Counter
Mode
0*
Input A Input B Input C
Count. inpt. Gate Reset
1
Count.inpt.
Direction.
Input
Reset
2
Count.inpt.
Direction.
Input
Gate
3
Adding Subtracting Reset
4
Adding Subtracting Gate
5
Adding Adding Reset
6
Channel A Channel B Reset
7
Channel A Channel B Gate
Function code F2, Display Row 1:
Edge
Evaluation
/Quadrat.
evaluation
0*
Single evaluation
1
Double evaluation
2
Quadruple evaluation
Function code F3, Display Row 1:
PNP/NPN-
Logic
0
NPN-8V-Level
1*
PNP 8-V Level
2
NPN TTL-Level
3
PNP TTL-Level
Function code F4, Display Row 1:
Input-
damping
(Attenu-
ation)
0
30 Hz damping (e.g. for mechanical
contacts)
1*
F max. (see chapter 4 and 10)
Function code F5, Display Row 1:
Set / Re-
set- Mode
0*
Reset to 0
1
Automatic reset to 0 after reaching
Preset 2
2
Set to Preset 2
3
Automatic set to Preset 2 after
reaching 0
Pulse counter