Function code F6, Display Row 1:
dynam./
static
Reset
0*
Static reset (reset as long as the signal
is applied)
1
Dynamic Reset (ready to count after
reset (even if reset signal is applied for
a longer time)
Function code F8, Display Row 1:
Mode
Preset 1
0*
P 1 normal preset; absolute to the
counter reading (coincidence signal)
1
P 1 as a trail preset with prefix
(relative to P 2)
2
P 1 as a trail preset symmetric trail
(relative to P 2)
3
P 1 and P 2 as a range signal
(Sign.1 < P 1, Sign.2 > P 2)
Function code F9, Display Row 1:
Output
signal
o*
Active On
1
Active Off
Pulse counter
Function code F10, Display Row 1:
Signal
time P 0
0
Disabled / No output signal
1
Bistable, reset with Preset 2 or Reset
2
0,02 s
3
0,05 s
4*
0,10 s
5
0,20 s
6
0,50 s
7
1,00 s
8
2,00 s
9
5,00 s
10
10,00 s
11
User setting 1 (0-599,99 s)
12
User setting 2 (0-599,99 s)
13
User setting 3 (0-599,99 s)
Pulse counter