User Manual
78 79
Timer
Function code F13, Display Row 1:
Stop after
reaching
the main
Preset
0*
No Stop when main Preset is reached
(P 2)
1
Stop when main Preset is reached (P 2)
Function code F14, Display Row 1:
Display
flashes
0*
no flashing
1
Flashes as long as P 0 is active
2
Flashes as long as P 1 is active
3
Flashes as long as P 2 is active
4
Flashes as long as 1 P is active
Function code F15, Display Row 1:
Display in
2nd Row
0
Preset 0
1
Preset 1
2*
Preset 2
3
Prescaler
4
Totalizer / Batchcounter
Function code F16, Display Row 1:
Start /
Stop via
Keyboard
(manual)
0*
Start / Stop locked via keys
UP key=Start; DOWN key = Stop
1
Start / Stop enabled via keys
UP key =Start; DOWN key =Stop
Function code F17, Display Row 1:
Power On
Reset
0*
Restore counter value
1
Reset at Power On
Function code F18, Display Row 1:
Output
Signal
Memory
0
Restart signal time after power fail
output switches
1*
Do not restart signal time after power
fail
Function code F19, Display Row 1:
Addtl.
Totalizer
0
Enabled
1*
Disabled
Timer