User Manual
82 83
Function code F32, Display Row 1:
Lock Pre-
set 1 Set-
ting
0*
P 1 Setting enabled
1
P 1 Setting locked / delayed
Function code F33, Display Row 1:
Lock Pre-
set 2 Set-
ting
0*
P 2 Setting enabled
1
P 2 Setting locked / delayed
Function code F34, Display Row 1:
Lock Pres-
caler Set-
ting
0*
PSC Setting enabled
1
PSC Setting locked / delayed
Function code F35, Display Row 1:
Lock
Mode
0*
10 seconds delay
1
Completely locked
2
Lock mode depends on keylock input
Timer
8 Shift Counter
8.1 Shift Counter Description
(Supplementing the general description under chapter 4)
Function:
2-shift counters enable the acquisition of 2 separate partial sums.
Counter input A acts on partial sum 1, whereas counter input B acts on partial
sum 2.
Both partial sums are counted positively; the total sum is calculated mathe-
matically and corresponds to the summed-up total (or respectively, the diffe-
rence) of the partial sums.
The total sum remains unchanged after resetting one of the partial sums.
Counter mode of operation:
The following counter modes of operation can be selected:
Difference counting and summation (totalizing)
Output signals - mode of operation:
The counter operates in the “coincidence” mode, i.e. the output signals are
enabled for the programmed period of time after reaching the selected Preset
value.
The total sum acts on Preset 0
Partial sum 1 acts on Preset 1
Partial sum 2 acts on Preset 2
Reset:
After a reset at input C, both partial sums and the total sum are reset.
When resetting via the application input it is possible to reset one or both of
the partial sums or the total sum, depending on the selected programming.
When resetting via the keyboard, only the value shown on the display is reset.
Totalizer:
The totalizer sums up all the input pulses, even if the partial sums and the to-
tal sum are reset. The totalizer can only be reset manually.
Shift Counter