User Manual

84 85
8.2 Scrolling between Total Sum and Partial Sums
The Shift key is used to scroll between the total sum and
partial sums 1 and 2.
If a partial sum is shown, SU1 or SU2 will appear flashing in the lower display
bar.
8.3 Signal diagrams - Inputs (PNP Logic)
Shift Counter
Total sum
Partial sum 1
Partial sum 2
Adding/Adding (F1= A A r)
Input A
Input B
Counter reading
Partial sum 1 1 2 3 4 5 6 7
Partial sum 2 1 2 3 4
Total sum 1 2 3 4 5 6 7 9 10 11
8.4 Signal Diagrams - Output signals
Shift Counter
Output signals - monostable
Coincidence signals P 0/Total Sum (F10), P 1/Partial sum 1 (F11), P 2/Partial sum 2 (F12) monostable
Preset 1 Preset 2 Preset 0
Counter reading Partial sum1 Partial sum 2 Total sum
P 1 (Relay)
Signal
time
P 2 (Relay)
Signal
P 0 electronic time
(Application output)
P 1 electronic
Signal
time
P 2 electronic
Signal time
Signal time
Adding/Subtracting (F1= A S r)
Input A
Input B
Counter reading
Partial sum 1 1 2 3 4 5 6 7
Partial sum 2 1 2 3 4
Total sum 1 0 1 0 1 0 1 1 2 3