User Manual

98 99
9.2 Signal Diagrams - Inputs and Outputs
9.3 Programming the Batch Counter Function Codes
Programming
mode
Change function
setting
Save and
change to next
function
Return to dis-
play mode
+ or
Keep pressed and
simultaneously
turn
Voltage On
press press press
Alternative display
of
Function codes
+
The function codes are displayed
as text in row 1.
By pressing both keys simultane-
ously you can change to the nu-
merical display (F 0 to F 35). After
pressing these keys once again the
number of the selectable options
will be displayed in addition. This
setting will be stored.
Batch Counter
Unidirectional count (F1 = C G r), Batch counter (F19 = bAtch),
Preset 2 (Main Preset = 5, Preset 1 (Batch Preset) = 3
Input A
Counter input
Reset Reset Reset
Preset 2
Preset 1
Counter Reading 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0
Batch Counter 1 2 3
Function code F0, Display Row 1:
Function No. Display Row 2
Factory
Setting
(Defaults)
0*
No function
1
All function codes are set to the
values marked with *
Function code F1, Display Row 1:
Counter
Mode of
Operation
0*
Input A Input B Input C
Count
Input
Gate Reset
1
Count
Input
Directional
input
Reset
2
Count
Input
Directional
input
Gate
3
Adding Subtracting Reset
4
Adding Subtracting Gate
5
Adding Adding Reset
6
Channel A Channel B Reset
7
Channel A Channel B Gate
Batch Counter