User Manual
106 107
Function code F15, Display Row 1:
Display in
2nd row
0
Preset 0
1
Preset 1
2*
Preset 2
3
Prescaler
4
Batch counter or 2nd counter
Function code F16, Display Row 1:
External
Reset
signal
0
Only resets the counter
1
Only resets the batch counter
2*
Resets all counters
Batch Counter
Function code F17, Display Row 1:
Power On
Reset
0*
Restores the counter value
1
Reset at Power On
Function code F18, Display Row 1:
Output
signal-
Memory
0
Restart signal time after power fail
output switches
1*
Do not restart signal time after po-
wer fail
Function code F19, Display Row 1:
Batch-
Counter
or 2nd
totalizer
0*
Batch counter
1
2nd totalizer
Function code F22, Display Row 1:
Applica-
tion in-
put/
output
0
Prescaler output
1
Output Preset 0
Batch Counter