User Manual

110 111
Function code F33, Display Row 1:
Lock
Preset 2
Setting
0*
P 2 Setting enabled
1
P 2 Setting locked / delayed
Function code F34, Display Row 1:
Lock
Prescaler
Setting
0*
PSC Setting enabled
1
PSC Setting locked / delayed
Function code F35, Display Row 1:
Lock
Mode 0*
10 seconds delay
1
Completely locked
2
Lock mode depends on Keylock input
Batch Counter
10 Technical Data
General
Display LCD reflective,
Transflective positiv: black figures on back lighted ground
Transmissive negativ: white, red or green figures on black
ground 2 lines, counter reading/presettings 6-digits; deci-
mal point (up to 4 decimals)
Digit hight 1st line 9.3 mm; 2nd line 7.2 mm
View angle 12 o‘clock
Supply voltage SELV: 12-30 VDC; protected against polarity reversal
SELV: 24 VAC, 50/60 Hz, ± 10%
115 VAC; 230 VAC, 50/60 Hz, ± 10%
100-240 VAC; 50/60 Hz, ± 10%
Current consump-
tion
12 ... 30 VDC < 200 mA,
12 - 30 VDC with backlight < 250 mA incl. sensor supply
24 VAC < 250 mA; including sensor supply
115/230 VAC < 50 mA; incl. sensor supply
100 - 240 VAC < 80 mA at 90 VAC; incl. sensor supply
Power consumption < 5 W
< 8 W switching power supply
Duty cycle 100%
Overload protection external fuse DC: 0,16 AT (IEC 127); DC: 0,2 AT (UL 198)
24 VAC: 315 mAT; 230 VAC: 32 mAT; 115 VAC: 63 mA T
100 - 240 VAC G-safety insert 630 mA/250V
Overload protection
Relay output
external fuse 230 V, 2,5 A mT
Sensor supply 24/115/230 VAC
AC-operation: 12-24 VDC (load dependent), max. 50 mA
90-260 VAC (switching power supply)
AC-operation: 24VDC/-5%, max. 115 mA
max. capacitive load = 470 µF
Technical Data