Storage of values NV-memory > 10 years
Electrical connec-
tions
Plug-in screw-type connections / Terminals
Cable cross-section 1...1.5 mm² with wire-end sleeves
Amplitude threshold < 2 V and > 8 V or < 1 V and > 4 V at TTL-level amplitude
max. 40 VDC
Active edge programmable positive for PNP-input,
negativ for NPN-input
Input resistance approx. 10 kOhm
Count frequency max. 60 kHz (TTL 20 kHz): single-channel counting
max. 60 kHz (TTL 20 kHz): Different. counting and tota-
lizing channel (A+B together)
max. 30 kHz (TTL 20 kHz): phase discriminator single or
double evaluation
max. 15 kHz (TTL 15 kHz): phase discriminator, quadruple
evaluation
damped (attenuated) 30 Hz
-> Please pay attention to graphics on page 117
Pulse form any desired form (at max. frequency square 1:1)
Pulse duration min 17 ms (30 Hz); 8 µs (60 kHz)
Prescaler 0,0001 - 99,9999
Reset manual reset via keyboard
external reset static or dynamic programmable
pulse length min. 5 ms, automatic reset after reaching
Preset 2, (No pulse losses at max. counter frequency due
to automatic reset function).
via application input (programmable) and
programmable Power-On Reset
Set function Setting to Preset 0 (independent of reset)
Display and Preset
Range
- 999 999 up to + 999 999
Technical Data
Warning signal Display flashes when preset 0, 1 or 2 are active
Signal times 0,01 s to 599,99 s or bistable programmable
tolerance + 10ms
active On or Off
Relay Output
for P 1 and P 2
Change-over contact max. 250 VAC / 30 VDC / 5 A
Change-over contact min. 5 VAC / 5 VDC / 10 mA
delay < 10 ms
Transistor Output
for P 1 and P 2
PNP-output
12 - 30 VDC max. 50 mA at DC-supply
12 - 24 VDC max. 30 mA at AC-supply (24/115/230 VAC)
24 VDC, max 50 mA at AC-supply with switching power
supply
Application Output PNP-output
12 - 30 VDC max. 20 mA at DC supply
12 - 24 VDC max. 20 mA at AC supply (24/115/230 VAC)
24 VDC max. 20 mA at AC-supply with switching power
supply
Only for trafo-power-supply:
Current load of the outputs (Sensor 12-24 VDC, Out 1,
Out 2, Application-Output) is not allowed to exceed
65 mA in sum.
Counter
Counter mode of
operation Input A,B
Unidirectional; adding or subtracting; directional input;
Differential operation, add / sub; Summation (Totalizing)
add / add; Phase discriminator single, double or quadruple
evaluation
Control Input Reset; Gate
Preselect Mode Absolute or trail, Range signal /limit values (sign. 1 < P1,
sign. 2 > P 2)
Application In-
put/Output
Output: Prescaler-out, Preset 0-out, Direction-out
Input: addtl. counter input add / sub, Reset, Set,
Gate, Keylock, Hold, Teach in
Technical Data