User Manual

114 115
Batch Counter
Mode Batch counter with Preset or 2nd totalizer with Preset
Shift Counter
Counter Mode
of Operation
Differential counting add/sub, totalizing add/add
Tachometer
Measuring Principle Period (cycle) measurement (1/Tau)
Time base 1/min or 1/s
Min. frequency 1 Hz or 0,1 Hz
Limit values
pression
2 alarms with programmable startup sup +1 additional
upper limit value on the application output
Tachometer mode
of operation
Unidirectional add oder sub; directional input;Differential
add / sub; totalizing add / add; Phase discriminator single,
double or quadruple evaluation, A / B or (A-B) / A %
Application
Input/Output
Output: Preselect 0-out, Direction-out
Input: addtl. counter input add / sub, Keylock, Hold,
Teach in
Accuracy of the
tachometer function
Time base: ± 30 ppm
Measuring principle: Periodic measurement
Measuring time: min. 0,5s / max. 1s oder 10s
Measuring resolution: 0,4µs(<30 ppm)
Display resolution: 4 decimal places, 1 Digit = 100 ppm
Overall tolerance = Shown resolution + tolerance of timebase = 130 ppm
Technical Data
Timer
Measuring Principle Pulse-width or cycle duration measurement
Start Inp. A + Stop Inp. B; Start/Stop key
Time base Programmable in sec, min, h or hh.mm.ss
Resolution 1; 0,1; 0,01; 0,001; 0,0001
Function Single-pulse or cumulative measurement
Application In-
put/Output
Output: Preselect 0-out
Input: addlt. Run, Stop, Reset, Set, Keylock, Hold, Teach in
Accuracy of
the timer
Time base: ± 30 ppm
Start / Stop-point in time: 16 µs / 16 ms (not damped /
damped)
Resolution: 100 µs = 100 ppm
Overall tolerance = Shown resolution + tolerance of timebase = 130 ppm
Environmental conditions / Safety Rules
General design EN 61010-1 / IEC 61010-1
Protection Class II; EN 61010-1 / IEC 61010-1
Pollution degree V 2, EN 50178
EMC - Interference
immunity
EN 61326-1 industrial environment *
EMC - Emission EN 61326-1 Class B *
Ambient tem-
perature
0°... 50°C EN 60 068-2-1/2
0°... 45°C with block assembly
0°... 50°C in single row assembly
Storage tem-
perature
- 20°... + 65°C EN 60 068-2-1/2
Climate
Altitude
40°C / 93% rel hum. class 4K4H, EN 60 068-2-78
25 - 50°C / 93% rel hum., cyclic, EN 60 068-2-38
up to 2000m
Technical Data