User Manual

116 117
Degree of pro-
tection
IP 65 front side; EN 60529
IP 20 terminals
Vibration resistance 10 m/s² (10 ... 150 Hz); EN 60 068-2-6
Shock resistance 100 m/s² (18 ms); EN 60 068-2-27
Resistence to
chemicals
Frontfoil acc. to DIN 42 115-2
Approvals UL, CSA: E 338588
RoHS compliant
Mechanical Data
Installation Front-panel installation with tenter (frame) Front panel
thickness max. 11 mm
Dimensions 48 mm x 48 mm x 118 mm, installation depth 110 mm
DIN 43700
Front-panel cutout 45 mm x 45 mm + 0,3 mm
Weight approx. 200 g
* For cable length > 30 m, for connection to a DC-supply-network and input
level TTL an additional protection circuit is necessary.
Technical Data Technical Data
The counting frequencies were determined by using a signal generator with an output resistance of 50 .
0
10
20
30
40
50
60
70
80
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Counting frequency according to signal voltage - Tico 77x
Signal Voltage [V]
Counting Frequency [kHz]
NPN-H
PNP-H