Datasheet
1/4 Relay catalogue
Safety Relay H-468
General
•4or6contacts
•Forced guided contact set
•According to EN50205 application type A
•Ambient temperature –25…+80°C
•Soldering heat resistance 260°C/5s
•RoHScompliance
Connections
•Soldering pins for PCB,pre-soldered with Sn100
Drive
•Direct current,polarized monostable
Approvals
•cUL/US*•TÜV*
(*for 6contacts pending)
Standards
• EN 50205 • IEC 61810-1 • UL 508
Insulation
Size 1
Size 2
Dimensions LxWxH(inmm) Size 1:44,6x12,5x30
Size 2:50x12,5x30
Shock resistance NO-contact/NC-contact 10/9g,16mshalf sinus
Vibration resistance NO-contact/NC-contact 5/5g,5–200Hz
Operating time NC-contact,contact opens typical 15ms
Operating time NO-contact,contact closes typical 17ms
Releasing time NO-contact,contact opens typical 6ms
Releasing time NC-contact, contact closes typical 8ms
Mechanical service life (without load)>10
7
cycles
Weight Size 1:35g
Size2:38g
Technical Data
mechanical
Max. switching capacity AC1.500VA,DC*W
Max. switching voltage AC230/240V,DC*V
Max. switching current 8A
Size 1
Constant current I
th
2
6A
Constant current I
th
2
at same time over 2 contacts 4,2A
Constant current I
th
2
at same time over 3contacts 3,5A
Size 2
Constant current I
th
2
6A
Constant current I
th
2
at same time over 2contacts 5,2A
Constant current I
th
2
at same time over 3contacts 4,2A
Constant current I
th
2
at same time over 4contacts 3,7A
Switching capacity AC-15230/240VIe=4/2A(contact AgNi/AgSnO
2
)
DC-1324VIe=2/1,5A(contact AgNi/AgSnO
2
)
Electrical service life (with nominal load) >10
5
cycles
Short-circuit capacity 1.000A/AC230V 6AgL/gG-fuse
*see DC-switching capacity
Technical Data
electrical
Over voltage category (Ü)IIIB-I=Basic insulation
Degree of pollution (V)2V-I=Reinforced (double) insulation
Insulating material group II
*Contactgroup AandBsee connection grid
Insulation
Nominal voltage network system
Air-/ Test voltage
between
AC120/240VAC230/400 V
creeping distance 50Hz/60s
Contact–Contact V-IB-I>3mmAC2.000V
Contactset –Drive V-IB-I>3mmAC2.500V
Insulation
Nominal voltage network system
Air-/ Test voltage
between
AC120/240VAC230/400 V
creeping distance 50Hz/60s
Drive-contact-
group A*V-IB-I>3,0mm1.500V
Drive-contact-
group B*V-IV-I>5,5mm3.000V
Contacts within
contactgroup AV-IB-I>3,0mm1.500V
Contacts within
contactgroup BV-IB-I>3,0mm1.500V
Contactgroup Aand BV-IV-I>5,5mm3.000V