Corp. Fryer User Manual

Model OFE/OFG/OEA/OGA-341, 342
2-20. HIGH TEMPERATURE
LIMIT CONTROL
(ELECTRIC)
(Continued)
4. Pull back cardboard cover and remove the two electrical wires
from the high temperature limit control. Figure 2-66.
Figure 2-66 5. Manually reset the control, then check for continuity between
the two terminals after resetting the control. If the circuit is
open, replace the control, then continue with this procedure.
(If the circuit is closed, the high limit is not defective. Re-
connect the two electrical wires.)
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle, to the frypot
to be worked on. Be aware the other control on 2-frypot
units will have power.
1. Drain the shortening from the frypot.
Figure 2-67
2. Remove capillary from brackets on upper part of element.
Figure 2-67.
3. Remove capillary bulb from bulb holder inside the frypot.
Figure 2-68
2-24 1003