Corp. Fryer User Manual

Model OFE/OFG/OEA/OGA-341, 342
2-5. POWER SWITCH (Continued)
4. With control panel removed, and the wires off the switch, push
in on tabs on the switch to remove from panel. Figure 2-12.
5. Replace with new switch, and reconnect wires to switch.
6. Replace the control panel.
Figure 2-12
2-6. TEMPERATURE PROBE The temperature probe relays the actual shortening temperature
REPLACEMENT (Gas) to the control board. If it becomes disabled, “E06” shows in the
display. Also, if the shortening temperature is out of calibration
more than 10°F or C°, the probe should be replaced. An Ohm check
can be performed also. See chart below.
1. Remove electrical power supplied to the fryer.
Figure 2-13
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain the shortening from the frypot.
3. Remove the control panel and heat shield from control area.
Figure 2-13.
4. Using a ½ inch wrench, remove the nut on the compression
Figure 2-14 fitting. Figure 2-14.
806 2-5