Corp. Fryer User Manual

The following checks, are performed with the wall
circuit breaker on, and the Power/Pump Switch in the
ower” position. Extreme caution should be taken.
ake connections before applying power, take reading,
and remove power by unplugging the power cord, or
by turning off the wall circuit breaker, before remov-
ing meter leads or electrical shock could result.
5.
ith power re-applied and in a heat-up mode, check the
power going to both contactor coils. This is to be sure
power is going to the contactors.
If no voltage is found going into the coils, the
and drain switch for the primary contactor.
Section.) For the heat contactor, check wi
If either contactor is defective it must be replaced as follows:
Remove electrical power supplied to the fryer by
unplugging power cord or turning off the wall circuit
breaker, or electrical shock could result.
emove only those wires directly connected to the
contactor being replaced. Label the wires.
2. Remove the two mounting screws on the base plate and
remove standard contactor (primary). Proceed to step 5.
3. Remove the two nuts securing the mercury contactor
bracket to the base plate and remove bracket.
4. move the two screws securing the mercury contactor
the bracket and remove contactor.
5. Install new contactor in reverse order of previous steps.
nstall control panel.
econnect power to fryer and test the fryer for proper