Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Henny Penny Blast Chiller/Freezer BFR/BCR-350 BCC/BCR-175 BCC/BCR-140
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 LIMITED WARRANTY FOR HENNY PENNY APPLIANCES Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the original purchaser only for Henny Penny appliances and replacement parts: NEW EQUIPMENT: Any part of a new appliance, except lamps and fuses, which proves to be defective in material or workmanship within two (2) years from date of original installation, will be repaired or replaced without charge F.O.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 TABLE OF CONTENTS Section Page Section 1. INTRODUCTION ................................................................................................................... 1-1 1-1. Henny Penny Blast Chiller ........................................................................................... 1-1 1-2. Features ....................................................................................................................... 1-1 1-3.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 1. INTRODUCTION 1-1. BLAST CHILLER/ The Henny Penny Blast Chiller are designed to carry out fast refrigeration of food products. The units are electronically controlled for easy use and for consistent operation. The BCC/BCR-140, will chill up to 140 lbs (65 kg) of product, the BCC/BCR-175 will chill up to 175 lbs (80 kg), and the BCR-350 will chill up to 350 lbs (160 kg) of product. The BFR-350 chills and freezes up to 350 lbs.
Henny Penny 1-5. SAFETY Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 The Henny Penny Blast Chiller has may safety features incorporated. However, the only way to ensure a safe operation is to fully understand the proper installation, operation, and maintenance procedures. The instructions in this manual have been prepared to aid you in learning the proper procedures. Where information is of particular importance or safety related, the words WARNING, CAUTION, and NOTE are used.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 2. INSTALLATION 2-1. INTRODUCTION This section provides the installation for the Henny Penny Blast Chiller. NOTE Installation of this unit should be performed only by a qualified service technician. Do not puncture the skin of the Blast Chiller with drills or screws, as component damage or electrical shock could result. Also, if the unit is shipped with a compressor, Do Not lay the unit on its side.
Henny Penny 2-2. UNPACKING (Continued) Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4. 5. 6. Open door and remove packing from the inside of the unit. Peel off any protective covering from the exterior of the cabinet. Your Blast Chiller is now ready for operation. If the blast chiller has been laid on its side, the unit must be sitting upright for at least an hour before applying power to the unit. Check all components for signs of being loose or damaged, and make sure the system has refrigerant.
Henny Penny 2-3. ELECTRICAL (Continued) 2-4. LOCATION Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Refer to the table below for electrical ratings for both models. Model No. Volts Watts Amps Freq.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 2-5. REFRIGERANT INFORMATION Design Pressure High Low Refrigerant Type Amount of Refrig. 2-6. REFRIGERATION CAPACITIES BCC-140 R404A 6 lbs. (2.7 kg) 406 psig (28 bar) 102psig (7 bar) BCC-175 R404A 5.5 lbs. (2.4 kg) 406 psig (28 bar) 102 psig (7 bar) BCC/BCR-140 -4o F (-20o C) at 6,800 BTU/hr (2.0 kw) 32o F (0o C) at 16,000 BTU/hr (4.7 kw) BCC/BCR-175 -4o F (-20o C) at 11,300 BTU/hr (3.3 kw) 32o F (0o C) at 38,800 BTU/hr (9.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 3. OPERATION 3-1. INTRODUCTION This section provides operating procedures for the Blast Chiller. Sections 1, 2, and 3 should be read, and all instructions should be followed before operating the cabinet. This section contains an explanation of all controls and components and information on operating procedures and daily maintenance.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-2. OPERATING CONTROLS (Continued) Fig. No. Item No. Description 3-1 7 Select Button The Select button is used to choose between a timing cycle or a cycle using the food probe. 3-1 8 Fan LED The Fan LED is a green light which illuminates when the fan is running. 3-1 9 Compressor LED The Compressor LED is a green light which illuminates when the compressor is running.
Henny Penny 3-3 Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100
Henny Penny 3-3. BASIC OPERATION Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 The Henny Penny Blast Chillers can chill food products with a core temperature of 149ºF (65ºC), down to 40ºF (4ºC) within 4 hours (room ambiant temperature may impact time it takes to reach the desired temperature). But, for the above statements to be accurate, the following conditions must be met: a. The food product must not be thicker than 1¾ to 2 inches (40 to 50 mm.) b.
Henny Penny 3-3. BASIC OPERATION (Continued) Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 5. Press the Select button to choose the food probe mode or the timing mode. With the Frigiprobe mode selected, the digital display will alternately show the core temperature of the product, and the elapsed time of the cycle. If the timing mode is selected, the digital display will alternately show the air temperature and the time (hours and minutes) remaining in the cycle.
Henny Penny 3-3.
Henny Penny 3-4. DE-ICING Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Henny Penny recommends to perform the de-icing process after every 3 cycles, and at the end of each day. This will eliminate any ice that may have formed around the evaporator during the chilling cycle. Failure the follow this procedure will increase the time it takes to cool the product and may lead to unsafe product. 1. Remove all product from the unit. 2. Close the door. 3. Press the ON/OFF button to turn the unit on. 4.
Henny Penny 3-5. CLEANING Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Daily: 1. Remove all electrical power supplied to the unit by turning off the wall circuit breaker. 2. Remove all product from the unit. 3. Remove the racks and pans from the unit and clean with soap and water at a sink. 4. Clean all surfaces with a soft cloth, soap and water. DO NOT USE ABRASIVE CLEANSERS.
Henny Penny 3-5. CLEANING (Continued) Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3. Use a vacuum cleaner, or soft brush to remove the dust, or other obstructions from the condenser. 4. Finish cleaning with compressed air if possible. DO NOT use a wire brush to clean the condenser, or damage to the condenser could result. 5. Replace the front panel, and reconnect the electrical supply, and unit is now ready for use. 3-6. SEASONAL OR PROLONGED SHUTDOWN 1.
Henny Penny 3-7. PROGRAMMING 300 Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Information about the operation settings can be accessed by pressing the Alarm button. These settings can also be changed while in the different steps. The following information can be accessed: NOTE After pressing the Alarm button, a delay will occur before the desired number will appear in the display, and the number in the left column will show for 2 seconds. You then only have 12 seconds to change the setting. 00 1.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING (Continued) The holding temperature can be changed at this time by using the Up and Down buttons. Factory setting for air temperature is 37ºF (3ºC). The minimum temperature setting is 32ºF (0ºC), and the maximum temperature is 50ºF (10ºC). 06 7. Maximum duration of de-icing cycle (minutes). Press the Alarm button 7 times and the digital display will show the time duration of the de-icing cycle.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING (Continued) 11. 10 The duration of time the temperatures, (in 9 and 10 above), must remain at before the alarms will sound. Press the Alarm button 11 times and the digital display will show the time at which the high and low temperatures (no. 9 and 10 above) must remain at, before the alarm will sound.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING (Continued) 14. 20 Blast chilling, low side air temperature limit, when using the Frigiprobe, in step 12 of this section. Press the Alarm button 14 times and the low side air temperature, at which the compressor cycles on and off, will show in the display. This temperature is used in preventing the product from freezing, while in the chilling mode, which is described in step 12.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING (Continued) 17. 23 Frigiprobe temperature for when the buzzer sounds at the start of a cycle. Press the Alarm button 17 times, and the temperature that the buzzer will sound when the product has reached the “danger zone” temperature, and must be cooled to a “safe” temperature within the recommended time, will be shown in the display.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 4. TROUBLESHOOTING 4-1. INTRODUCTION This section provides troubleshooting information in the form of an easy to read table. If a problem occurs during the first operation of a new cabinet, recheck the installation per section 2 of this manual. Before troubleshooting always recheck the operating procedure per section 3 of this manual. 4-2. TROUBLESHOOTING To isolate a malfunction proceed as follows: 1.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-2. TROUBLESHOOTING (Continued) ALARMS Display AL-5 AL-6 Cause Correction Temperature too low in the hold mode. Faulty control board - replace control board. Faulty contactor - replace contactor. Temperature too high in the hold mode. Problem The evaporator is iced-up after a de-icing cycle. Faulty control board - Replace board. Door opened too much - Make sure door stays closed as much as possible.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-2. TROUBLESHOOTING (Continued) Problem Slow to decrease in temperature (decline in performance) Display temperature does not match the actual inlet air temperature. (No alarm) Green compressor indicator light on and the compressor not working, or working sometimes. Cause Condenser obstructed by dirt. Clean the Condenser. Evaporator iced up. Perform a de-icing cycle. Refrigerating problem Check refrigeration circuit and components.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-2. TROUBLESHOOTING (Continued) Problem Green compressor indicator light off and compressor is working. Cause Voltage across terminals 10-11 of control board: - Control board relay bad Correction Replace control board. No voltage across terminals 10-11 of control board: - Faulty contactor.Replace contactor. Green fan indicator light on and fan(s) not working. Voltage across terminals 8-9 of control board.
Henny Penny 4-5 Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100
Henny Penny 201 Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 5-1
Henny Penny 5-2 Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201
Henny Penny 201 Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 5-3
Henny Penny Item No. Part No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 20 21 21 22 22 23 24 25 26 26 27 27 27 28 28 29 29 30 30 30 31 31 9504.0205 9503.3692 9503.3700 9503.3759 9503.7719 9503.8436 9503.8428 9503.3726 9500.7936 9503.6232 9500.7209 9500.7209 9502.6563 9560.0334 9505.3963 9502.0400 9503.3643 9503.3650 9503.0185 9503.3601 9503.6224 9503.0920 9503.0912 9503.3304 9502.1846 9501.8644 9503.7784 9503.3312 9503.6190 9502.1762 9502.8668 9501.6283 9502.8676 9503.6174 9503.6158 9503.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Item No. Part No. 31 32 33 34 34 34 35 35 36 36 37 37 38 39 40 41 42 42 42 42 43 43 44 45 45 46 47 48 40 9500.8967 9500.7993 9503.6182 9502.5045 9550.4585 9550.6630 9543.0831 9542.5989 9541.6053 9541.7671 9505.3674 9505.4466 9501.9998 9541.8919 9542.5963 9542.7225 9543.0419 9543.0518 9543.0427 9543.0542 9502.8601 9501.4551 9502.8619 9502.8585 9501.4601 9502.8593 9503.6240 9503.4583 9503.
For Sales or Service Please Contact The Nearest Henny Penny Distributor 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. General Services 100 Hicks Ave. Medford, MA 02155 (800) 233-1033 Art Cole Associates Golden Street Industrial Park Meriden, CT 06450 (203) 237-7177 Globe-Monte Metro, Inc. 47-02 Metropolitan Avenue Ridgewood, NY 11385 (718) 786-5760 Guertin Dist. Inc. 5 Technology Drive East Syracuse, NY 13057-9713 (315) 437-4928 (800) 468-6336 Kreiser Distributing Co. 13800 Lincoln Highway N.
Henny Penny International Distributor Network U.S. Headquarters Henny Penny Corporation 1219 U.S. Route 35 West Eaton, OH 45320 USA Telephone: 937-456-8417 Fax: 937-456-1860 1. 2. 3. 4. 5. 6. 7. 8. 9. Representative Office Henny Penny Corporation Representative Office Parc dEntreprises de IEsplanade 2bis Rue Paul Henri Speak Saint Thibault des Vignes 77462 Lagny sur Mame Cedex, France Telephone: 33 (1) 60075600 Fax: 33 (1) 60071489 U.S.
40. 41. 42. 43. 44. 45. Lebanon Pro Kitchen Cahlfoun Building Kaslik - Main Road PO Box 1066 Jounieh Lebanon Telephone: 961-9-635-077 Fax: 961-9-635-059 Lithuania Master Group Baltic Master Dariaus Ir Girena 175 2038 Vilnius, Lithuania Telephone: 3702-306-528/529 Fax: 3702-306-533 Malaysia SCC Corp. Sdn. Bhd. 19-21 Jalan Hujan Taman Overseas Union 58200 Kuala Lumpur, Malaysia Telephone: 60-3-77828384 Fax: 60-3-77818561 Malta C & H Bartoli Ltd.