Corp. Fryer User Manual
This section  provides  troubleshooting  information  in  the form  of  an  easy to  read guide.  Clearly  define 
the  problem  and  review  all  possible  causes. 
The following  guide  requires  voltage to be present  when  troubleshooting  the  control.  When  the 
guide  refers  to  connecting  pins  on the  power  connector,  unplug  the  power  connector  from  the 
bo 
and refer  to  the  attached  illustration.  These are  numbered  1 through  9. Using  a strand 
of 
gauge wire,  connect  the pins as numbered  in the troubleshooting  guide.  Extreme  caution 
must  be taken  when connecting  these  pins  to  avoid  control  board  damage  or  electrical  shock. 
rr 
With  switch  in  COOK  position,  the  fryer  is 
completely  inoperative  (no power  switch  light). 
With  switch  in  COOK  position,  the  fryer  is 
completely  inoperative  (power  switch  light  on, 
pump  works) 
Control  operative  -  all lights  on  - primary  con- 
tactor  engages  - no  heat or  pressure 
Control  operative  -  all  lights  on  - no  heat  or 
pressure  - primary  contactor  does NOT  engage 
Control  operative  -  all lights  on  -  has  pressure 
Control  operative  -  all lights  on  -  heat  on  -  no 
pressure  - pressure  light  ON. 
Control  operative  -  all  lights  on  -  heat  on  -  no 
pressure  - pressure  light  OFF 
Check  to  see if  unit  has voltage 
Check  fuses 
Defective  power  switch 
Check  voltage  on  pins  1  and  7  on  power 
connector,  10 VAC 
If voltage is present,  check fuse on control  board 
If  fuse  is  defective,  replace  fuse 
If  fuse  is good, replace  control  board 
Drain  Valve  Open 
Defective  Drain  Switch 
Check  5  amp  fuse  located  on  heat  shroud 
- fuse  OK 
Check voltage  from  center  of fuse to  ground  - 
24 VAC 
Defective  transformer 
Connect pins  4 and  6 on the  power  connector 
If  contactor  eng 
- replace  control  board 
If  contactor  does 
engage, replace contactor 
Connect pins  3 and  6 on the  power  connector 
If  solenoid eng  - defective  control  board 
If  solenoid does  engage - defective solenoid 
coil  - 24 VAC 
Check  programming 