Corp. Fryer User Manual
   Model 8000 Computron 
1-3.  OPERATING CONTROLS  Refer to Figure 1-1. 
Fig. Item  Description     Function 
No. No. 
1-1  1    Lights when the control calls for heat; the elements or 
      burners come on and heat the shortening 
1-1  2  Digital Display  Shows all the functions of the Cook Cycle, program modes, 
      diagnostic modes, and alarms 
1-1  3    Lights when the solenoid closes and pressure starts to build 
    inside frypot 
1-1  4    Flashes when the shortening temperature is NOT at the 
      proper temperature for cooking product 
1-1  5    Lights when the shortening temperature is 5° F (3° C) below 
    to 15° F (9° C) above the cooking temperature, signaling the 
      operator that the shortening temperature IS at the proper 
      temperature for cooking product 
1-1  6    Press to display the following fryer information and status: 
   a.  The temperature of the shortening 
      b. The temperature setpoint 
   c.  Filter status 
      d. The number of times filtered today 
      e.  The average no. of filters per day 
      f.  No. of times Cook Cycle was stopped early today 
      g. No. of times Cook Cycle was stopped early in past week 
      e.  Oil Life Display (Only if “Change Oil” feature is enabled) 
      f.  Date and time 
      If pressed in the Program Mode, shows previous settings; 
      pressing this along with accesses the Information 
      Mode which has historic information on the operator and 
    fryer’s performance 
1-1  7 & 8    Used to adjust the value of the currently displayed setting in 
      the Program modes 
1-2                     1005 