Gas valve knob turned to the OFF Make sure the gas valve knob is
position
turned to the ON position
Blown fuse or tripped Reset breaker or replace fuse
circuit breaker at supply
box or control panel
Blown fuse in PC board Replace glass fuse in board
Faulty Power/Pump switch Check Power/Pump switch
per maintenance section on
the Power/Pump switch
Faulty cord and plug Check cord and plug and
power at wall receptacle
Faulty drain switch Check drain switch per
maintenance section on
drain switches
Faulty PC Board Remove and replace control
panel
Faulty high limit control switch Check high limit control
switch per maintenance
section on the high limit
Drain valve open Close drain valve
Possible faulty gas control With power removed from
valve fryer, check across elec-
trical leads of gas control valve
with multimeter, and gas
valve in ON position
Possible faulty temperature probe Replace temperature probe
Bad spark ignitor Replace spark ignitor
Low air pressure Clean or replace blower
Replace air pressure switch
Faulty ignitor module Replace module
Spark ignitor or f ame sensor out of The spark ignitor must be 1/8 inch
adjustment from the pilot hood, and 1/4 inch
from the f ame sensor
1-8 1002
Problem Cause Correction
HEATING OF SHORTENING SECTION
Shortening will not heat
1-3. TROUBLESHOOTING