1-4. ERROR CODES (Continued)
CE Only - Along with error codes from preceding page, CE
units have the following self-diagnostic error codes:
DISPLAY CAUSE PANEL BOARD CORRECTION
“E-10” High limit Allow unit to cool (15-20 minutes), reset the high limit by
manually pushing up on red reset button; if high limit does
not reset, high limit must be replaced per section 2-4
“E-15” Drain Switch Close the drain using drain valve handle; if display still
shows “E-15,” check the drain microswitch per section 2-22
“E-20A” Air Pressure Press the Timer button to try the ignition process again;
Switch Failure if “E-20A” persists, call Henny Penny’s Service Depart-
(stuck closed) ment
“E-20B” Draft Fan or Press the Timer button to try the ignition process again; if
Air Pressure “E-20B” persists, call Henny Penny’s Service Department;
(stuck open) Switch Failure Number of failures can be seen in Review
Usage (pg. 3-24) of Operator’s Manual, then press EXIT
COOL
“E-20C” Left Gas Module Press the Timer button to try the ignition process again; if
Failure “E-20C” persists, call Henny Penny’s Service Department
“E-20D” Right Module Press the Timer button to try the ignition process again; if
Failure “E-20D” persists, call Henny Penny’s Service Department
“E-20E” Both Modules Press the Timer button to try the ignition process again; if
Failure “E-20E” persists, call Henny Penny’s Service Department
“E-20F” Left Module Press the Timer button to try the ignition process again; if
No Flame Sense “E-20F” persists, call Henny Penny’s Service Department
“E-20G” Right Module Press the Timer button to try the ignition process again; if
No Flame Sense “E-20G” persists, call Henny Penny’s Service Department
“E-20H” Both Modules Press the Timer button to try the ignition process again; if
No Flame Sense “E-20H” persists, call Henny Penny’s Service Department