Corp. Fryer User Manual

Model 690
2-4. HIGH TEMPERATURE 11. Pull all excess capillary line from the frypot and tighten nut
LIMIT CONTROL into frypot wall.
(Continued)
Be sure capillary bulb of high limit is positioned so it does
not interfere with the carrier or get damages when clean-
ing the frypot.
12. With excess capillary line pulled out, tighten smaller nut.
13. Replace front panel.
14. Ref ll with shortening.
2-5. POWER/PUMP SWITCH The Power/Pump switch is a three-way rocker switch with a
center OFF position. With the switch in the POWER position,
the fryer operates. With the switch in the PUMP position, the
f lter pump operates, but the unit will not heat.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Checkout
1. Remove Control Panel.
2. Label and remove wires from the switch.
3. “OFF” Position - should be open circuit anywhere on the
switch.
4. “Power” Position. Check from: #5 to #6 closed circuit
#l to #2 closed circuit
5. “Pump” Position. Check from: #4 to #5 closed circuit
#3 to #2 closed circuit
Check across the jumpers on the wires of the Power/Pump
switch. These jumpers have resistors and capacitors which
may be faulty.
2-4 1002