2-5. POWER/PUMP SWITCH
(Continued)
Replacement
1. With control panel removed, and wires off the switch,
push in on tabs on the switch to remove from the panel.
2. Replace with new switch, and reconnect wires to switch
following the wiring diagram.
3. Replace the control panel.
2-6. TEMPERATURE PROBE Temperature Probe relays the actual shortening temperature
REPLACEMENT to the control. If it becomes disabled, “E-6” will show in the
display. Also, if the temperature is out of calibration more than
10°F, or 10°C, the temperature probe should be replaced. An
Ohm check can be performed also. See chart at end of this
section.
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain the shortening from the frypot.
3. Remove the Control Panel.
4. Using a 1/2” wrench, remove the nut on the compression
f tting.
5. Remove the temperature probe from the frypot.
6. Place nut and new ferrule on new temperature probe and
insert the temperature probe into the compression f tting
until it extends 1/2 inch (1.3 cm) into the frypot. Use the
temperature probe gauge provided in the temperature
probe kit to ensure proper placement in frypot. See
Figures 2-1 and 2-2.
806 2-5
Figure 2-1