2-19. GAS CONTROL VALVE The gas control valve sends regulated gas to burners when the
controller calls for heat. The control valve can be turned on
or off. In ON position, and power switch ON, a spark ignitor
lights a standing pilot, and when the control calls for heat, the
valve is opened and the burners are ignited.
Safety Precautions
TO AVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING GAS CON-
TROL VALVE DO THE FOLLOWING:
MOVE THE POWER/PUMP SWITCH TO THE
“OFF” POSITION.
DISCONNECT MAIN CIRCUIT BREAKER AT
THE WALL, OR UNPLUG THE POWER CORD.
TURN OFF THE MAIN GAS SUPPLY TO THE
FRYER AND DISCONNECT AND CAP SUPPLY
LINE TO FRYER.
Replacement
A voltage check at the control valve must be taken four (4)
seconds after the Power/Pump switch is turned to the
Power position.
1. Turn gas knob to the OFF position.
2. Remove cover from control valve.
3. Remove the wires from the control valve.
1002 2-17