SDS

_____________________________________________________________________________________________
Environmental precautions
Environmental precautions
Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. Do
not flush into surface water or sanitary sewer system.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Dam up. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal
binder, sawdust). Pick up and transfer to properly labeled containers.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Ensure adequate ventilation, especially in confined areas. Keep away from heat, sparks,
flame and other sources of ignition (i.e., pilot lights, electric motors and static electricity).
Take precautionary measures against static discharges. Use spark-proof tools and
explosion-proof equipment. All equipment used when handling the product must be
grounded.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep tightly closed in a dry and cool place. Keep in properly labeled containers. Keep away
from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and
static electricity).
Incompatible materials
Strong oxidizing agents. Strong acids. Strong bases.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
.
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Asphalt
8052-42-4
TWA: 0.5 mg/m
3
benzene soluble
aerosol fume, inhalable fraction
- Ceiling: 5 mg/m
3
fume 15 min
Limestone
1317-65-3
- TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
Solvent naphtha, petroleum,
medium aliphatic
64742-88-7
- TWA: 500 ppm
TWA: 2900 mg/m
3
-
Cellulose
9004-34-6
TWA: 10 mg/m
3
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
TWA: 1 mg/m
3
NIOSH IDLH Immediately Dangerous to Life or Health
Appropriate engineering controls
Engineering Controls
Showers
Eyewash stations
Ventilation systems.
Individual protection measures, such as personal protective equipment
Eye/face protection
Wear safety glasses with side shields (or goggles).
Skin and body protection
Wear protective gloves and protective clothing.
Respiratory protection
If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved
respiratory protection should be worn. Positive-pressure supplied air respirators may be
required for high airborne contaminant concentrations. Respiratory protection must be
_____________________________________________________________________________________________
Page 4 / 9
HE208 - WET PATCH ROOF CEMENT Revision Date 25-Jan-2016