Datasheet

Heraeus Sensor-Nite GmbH
Reinhard-Heraeus-Ring 23
D-63801 Kleinostheim
Germany
Phone +49 60 27 / 503-179
Fax +49 60 27 / 503-265
Platinum Resistance Temperature Detector M-FK 1020
F series PRTDs are designed for large volume applications where long term
stability, interchangeability and accuracy over a large temperature range are
vital. Typical applications are Automotive, White Goods, HVAC, Energy Man-
agement, Medical and Industrial equipment.
Specification : DIN EN 60751 (according to IEC 751)
Temperature range : -70°C to +500°C (continuous operation)
Tolerance class B - 70 °C to + 500 °C
Tolerance class A - 30 °C to + 350 °C
Tolerance class 1/3 B 0 °C to + 100 °C
Temperature coefficient : Tc = 3850 ppm/K
Leads : platinum clad nickel wire
Longterm stability : max. R
0
-drift 0,04% after 1000 h at 500 °C
Vibration resistance : at least 40 g acceleration at 10 to 2000 Hz
Shock resistance : at least 100 g acceleration with 8ms half sine wave
Environmental conditions : unhoused for dry environments only
Insulation resistance : > 10 M at 20 °C; > 1 M at 500 °C
Self Heating : 0,2 K/mW at 0 °C
Response time : water current (v = 0,4 m/s): t
0,5
= 0,2 s; t
0,9
= 0,4 s
air stream (v = 1 m/s): t
0,5
= 4,2 s; t
0,9
= 12,7 s
Measuring current : 100 : 1,0 to 3,0 mA
500 : 1,0 mA
1000 : 0,3 to 1,0 mA
Nominal Resistance R
0
Tolerance
Order Number
Blister Reel
100 Ohm at 0°C
for M-FK 1020
1 Pt 100
DIN EN 60751, class B 32 208 280
DIN EN 60751, class A 32 208 429
DIN EN 60751, class 1/3 B 32 208 428
500 Ohm at 0°C
for M-FK 1020
1 Pt 500
DIN EN 60751, class B 32 208 285
1000 Ohm at 0°C
for M-FK 1020
1 Pt 1000
DIN EN 60751, class B 32 208 286
DIN EN 60751, class A 32 208 439
DIN EN 60751, class 1/3 B 32 208 483
The measuring point for the nominal resistance is situated at 8 mm from the end of the sensor body
11 / 1998
1,9
±0,15
±0,1
0,9
0,2
0,01
+
-
10
1,0
-
+
9,5
±0,15