Haymaker Brochure and Instruction Manual

Hercules
®
HAYMAKER
Tankless Water Heater Descaler
DESCALING PROCEDURE:
1. Disconnect power to water heater.
2. Close hot and cold isolation and service valves and remove service
caps.
3. Pour contents of 1 quart Hercules Haymaker Tankless Water Descaler
into a bucket containing 1 gallon of water.
4. Connect a hose to pump, and other end of same hose to cold service
valve. Place pump in bucket.
5. Connect a second hose to hot service valve. Place other end in bucket.
6. Plug pump into grounded receptacle. Do not operate pump in less than
5 pints of liquid.
7. Allow pump to circulate solution through heater for 30 to 45 minutes.
Unplug pump.
8. Close cold service valve, and replace service cap.
9. Disconnect the hose from the pump and remove pump from bucket.
Discard the solution.
10. Flush water heater for 3 to 5 minutes or until water ows water-clear by
opening the cold isolation valve and allowing water to exit through the
hot service valve into the drain or bucket, empty as needed during the
process. After complete ush, drain water should be near pH 6-8.
11. Close the hot service valve. Remove the hose from the service valve and
replace the service cap.
12. Open the hot isolation valve.
13. Connect power to water heater and return appliance to service.
©2014 Oatey SCS. All Rights Reserved.
This information is based on data believed to be reliable but Oatey makes no warranties, express or implied, as to its accuracy and assumes no liability arising out of
its use. The data listed falls within the normal range of product properties but should not be used to establish specication limits or used alone as the basis of design.
Oatey’s liability to purchasers is expressly limited to the terms and conditions of sale.
Oatey is a trademark of Oatey Co. All other trademarks can be found on www.oatey.com.
4700 W. 160th St.
|
Cleveland, OH 44135
|
800.321.9532
|
Fax: 800.321.9535
|
www.oatey.com
LCS940B
216.267.7100 / 800.321.9532
www.oatey.com
DISTRIBUTED BY:
Additional Electric Pump Data:
Max output – 550 GPH
2.5 GPM @ 8' TDH
Air lled motor
Includes pre-lter to prevent debris from
re-entering heat exchanger
UL listed