SDS
Most important
symptoms/effects, acute and
delayed
Direct contact with eyes may cause temporary irritation.
Indication of immediate
medical attention and special
treatment needed
Treat symptomatically.
General information
Ensure that medical personnel are aware of the material(s) involved, and take precautions to
protect themselves.
5. Fire-fighting measures
Suitable extinguishing media
Alcohol resistant foam. Water fog. Dry chemical powder. Carbon dioxide (CO2).
Unsuitable extinguishing
media
Do not use water jet as an extinguisher, as this will spread the fire.
Specific hazards arising from
the chemical
During fire, gases hazardous to health may be formed.
Special protective equipment
and precautions for firefighters
Self-contained breathing apparatus and full protective clothing must be worn in case of fire.
Fire fighting
equipment/instructions
Move containers from fire area if you can do so without risk.
Specific methods
Use standard firefighting procedures and consider the hazards of other involved materials.
General fire hazards
No unusual fire or explosion hazards noted.
6. Accidental release measures
Personal precautions,
protective equipment and
emergency procedures
Keep unnecessary personnel away. For personal protection, see section 8 of the SDS.
Methods and materials for
containment and cleaning up
Large Spills: Stop the flow of material, if this is without risk. Use water spray to reduce vapors or
divert vapor cloud drift. Dike the spilled material, where this is possible. Cover with plastic sheet to
prevent spreading. Absorb in vermiculite, dry sand or earth and place into containers. Following
product recovery, flush area with water.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination.
Never return spills to original containers for re-use. For waste disposal, see section 13 of the SDS.
Environmental precautions
Avoid discharge into drains, water courses or onto the ground.
7. Handling and storage
Precautions for safe handling
Avoid prolonged exposure. Use care in handling/storage.
Conditions for safe storage,
including any incompatibilities
Store in original tightly closed container. Store away from incompatible materials (see Section 10
of the SDS).
8. Exposure controls/personal protection
Occupational exposure limits
US. Workplace Environmental Exposure Level (WEEL) Guides
Value
Type
Form
Components
TWA 10 mg/m3 Aerosol.Propylene glycol (CAS
57-55-6)
Biological limit values
No biological exposure limits noted for the ingredient(s).
Appropriate engineering
controls
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates
should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation,
or other engineering controls to maintain airborne levels below recommended exposure limits. If
exposure limits have not been established, maintain airborne levels to an acceptable level.
Individual protection measures, such as personal protective equipment
Eye/face protection
Wear safety glasses with side shields (or goggles).
Skin protection
Hand protection
Wear appropriate chemical resistant gloves.
Other
Wear suitable protective clothing.
Respiratory protection
In case of insufficient ventilation, wear suitable respiratory equipment.
Cryo- Tek Original and Cryo- Tek - 100 Antifreeze SDS US
924648 Version #: 01 Revision date: - Issue date: 05-February-2015
2 / 6