ANSI Material Safety Data Sheet

Hercules Chemical Company, Inc.
MSDS # 322 - Hercules Megabubble Leak Detecto
r
_
____________________________________________________________________________________________
Hercules Megabubble Leak Detector – MSDS # 322
Page 3 / 6
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Glycerol TWA: 10 mg/m
3
TWA: 10 mg/m
3
NIOSH IDLH: Immediately Dangerous to Life or Health
Engineering Controls
Showers
Eyewash stations
Ventilation systems
Personal Protective Equipment
Eye/face Protection
If splashes are likely to occur, wear Goggles.
Skin Protection
No special protective equipment required
Respiratory Protection
No special protective equipment required.
General Hygiene Considerations
Handle in accordance with good industrial hygiene and safety practice
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Blue
Odo
r
Odorless
Physical State
Liquid
pH
7
Autoignition Temperature
Not applicable
Boiling Point/Range
100°C / 212°F
Melting Point/Range
No data available
Flammability Limits in Ai
r
No data available
Specific Gravity
1
Water Solubility
Soluble in water
Solubility
No data available
V
OC Content
435 g/l
iscosity
130 cps
10. STABILITY AND REACTIVITY
Chemical Stability
Stable under recommended storage conditions.
Conditions to Avoid
None known based on information supplied.
Incompatible Materials
Strong oxidizing agents.
Hazardous Decomposition Products
None known based on information supplied
Hazardous Polymerization
Hazardous polymerization does not occur.
11. TOXICOLOGICAL INFORMATION
Acute Toxicity
Product Information
Product does not present an acute toxicity hazard based on known or supplied information
Chemical Name LD50 Oral LD50 Dermal LC50 Inhalation
Propylene Glycol 20000 mg/kg ( Rat ) 20800 mg/kg ( Rabbit )
Glycerol 12600 mg/kg ( Rat ) 10 g/kg ( Rabbit ) 570 mg/m
3
( Rat ) 1 h