ANSI Material Safety Data Sheet

Hercules Chemical Company, Inc.
MSDS # 349 - PVC CEMENT CLEAR MEDIUM BDY, FAST SET
_
___________________________________________________________________________________
PVC CEMENT CLEAR MEDIUM BDY, FAST SET – MSDS # 349
Page 2 / 5
3. COMPOSITION/INFORMATION ON INGREDIENTS
Component CAS No. Percentage OSHA PEL ACGIH TLV Other limits
Tetrahydrofuran 109-99-9 40-70 200 ppm 200 ppm
Methyl ethyl Ketone 78-93-3 5-10 200 ppm 200 ppm
Cyclohexanone 108-94-1 5-10 50 ppm 20 ppm
PVC Resin 9002-86-2 10-30 15 mg/m3 10 mg/m3
Fumed Silica 112945-52-5 1-5 15 mg/m3 10 mg/m3
HMIS Hazard Rating: 3 4 1 G
4. EMERGENCY AND FIRST AID PROCEDURES.
Eye: Immediately flush eyes with large quantities of water, for at least 15 minutes, holding the eyelids apart.
Get immediate medical attention.
Skin: Wash with soap and water. Remove contaminated clothing. Wash contaminated clothing before reuse. If
irritation develops, get medical attention.
Inhalation: Remove person to fresh air. If not breathing, give artificial respiration. If breathing is difficult, have
qualified person administer oxygen,. Call a doctor.
Ingestion: DO NOT INDUCE VOMITING. If conscious, give 1-2 glasses of water to dilute. NEVER GIVE
ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. Call a doctor immediately.
5. FIRE FIGHTING MEASURES
Flashpoint: 6°F (TCC) (Based on THF)
Flammable Limits: LEL: 2.0 % UEL: 11.8 %
Autoignition Temperature: Not determined
Extinguishing Media: Foam, Dry Chemical or Carbon Dioxide.
Unusual Fire or Explosion Hazards: Vapors are heavier than air, and will travel considerable distance to
source of ignition causing a flashback. On long standing may form peroxides which may cause violent reactions
especially upon evaporation to dryness.
Special Fire-Fighting Instructions: Handle as flammable liquid. Firefighters should wear positive pressure
self-contained breathing apparatus and chemical goggles. Water may be ineffective but should be used to keep
fire exposed containers cool.
Hazardous Combustion Products: Carbon Dioxide and Carbon Monoxide are formed. Irritating peroxide
fumes are formed when heated to decomposition.
6. ACCIDENTAL RELEASE MEASURES
Eliminate all sources of ignition. Ventilate area. Wear appropriate personal protection equipment. Absorb with
inert absorbing material and dispose of with solid waste according to Federal, State and Local regulations.
Wash spill area with water. Do not flush wash water into confined areas.
7. HANDLING AND STORAGE
Handling: Do not get in eyes, on skin or clothing. Avoid breathing vapors. Keep product away from heat,
sparks and open flames and all sources of ignition. Use with adequate ventilation. Wash thoroughly with soap
and water after handling. Keep containers closed when not in use.
Storage: Store in a cool, dry, well ventilated area away from incompatible materials. Store only in original
container. Keep containers closed when not in use, and away from open flame or other sources of ignition.