User Manual
MCM-20.4 Iss1
Preliminary User Guide v1.1
9
SUBGROUP INSERT RETURNS 1-4 AND AUXILIARY INPUTS:
TASCAM DSUB
CHANNEL #
SUBGROUP INSERT RETURNS 1-4 AND
AUX INPUTS
1
SUBGROUP INSERT RETURN #1
2
SUBGROUP INSERT RETURN #2
3
SUBGROUP INSERT RETURN #3
4
SUBGROUP INSERT RETURN #4
5
AUXILIARY INPUT #1 (L)
6
AUXILIARY INPUT #2 (R)
7
AUXILIARY INPUT #3 (L)
8
AUXILIARY INPUT #4 (R)
It is worth noting that, in order to avoid ground loops, the Dsub ground connections are lifted
on the MCM20.4 side, leaving the ground paths of your DSUB snakes only acting as shields and
preventing any current returns.